AC voltage : 6V/60V/600V
DC voltage : 6V/60V/600V
Frequency : 9.999Hz/99.99Hz/999.9Hz/9.999KHz/99.99KHz/999.9KHz/9.999MHz
Resistance : 600W/6kW/60kW/600kW/6MW/60MW
Temperature : -20 to 1000°C, -4 to 1832°F
Gross weight : 0.500Kg
UK type plug socket tester pro with RCD GFCI Voltage Measurement and LED indication
Product warranty instructions
Product certification is your instrument in the use of failure, seeking repair services must have, and then you purchase the invoice at the same time to be effective.
1) When your multimeter in use fails, please contact our maintenance department as soon as possible, consultation, so as not to delay your use and warranty period.
2) The product of the Company from the date of purchase from the warranty service. In the event of failure during the warranty period, the company professionals to confirm the reasons for the failure of non-users, the company free warranty service.
3) If the warranty period is exceeded, the cost will be charged (repair fee + component fee).
4) Even during the warranty period, maintenance fees are charged in the following cases.
⑴ due to improper use of the user or accidental disaster events and damage to the components and burn the circuit board.
⑵ non-professional staff of the company open shell, inspection, modification.
⑶ failure to comply with the instructions specified in the operation.
⑷ not the company's products do not maintain repair.
⑸ due to maintenance caused by postage, transportation and other users themselves.
⑹ multimeter battery, table pen, temperature probe and other functional accessories and supplies are not free warranty list.
 
  
 Technical indicators
  
 Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
 3.2.1 True rms zero input
 3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.
 3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.
 3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.
  
  
  
 3.2.2 DC voltage
| Range | Resolution | Accuracy | 
| 6V | 0.001V | ±(0.5% of reading + 5 words) | 
| 60V | 0.01V | |
| 600V | 0.1V | ±(0.8% of reading + 5 words) | 
- Input impedance: 10MΩ
 - Maximum input voltage: 600V DC or 600V AC (rms)
 Note:
 In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
 This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
  
  
 3.2.3 AC voltage
  
| Range | Resolution | Accuracy | 
| 6V | 0.001V | ±(0.8% of reading + 3words) | 
| 60V | 0.01V | |
| 600V | 0.1V | ±(1.0% of reading + 10words) | 
- Input impedance: 10MΩ
- Maximum input voltage: 600V AC (RMS) or 600V DC
- Frequency range: 40 ~ 1000Hz True RMS
Note:
 In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
 This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
  
  
  
 3.2.4 Alternating current
  
| Range | Resolution | Accuracy | 
| 600.0uA | 0.1uA | ±(1.5% of reading +10words) | 
| 6000uA | 1uA | |
| 60.00mA | 0.01mA | |
| 600.0mA | 0.1mA | |
| 6A | 0.001A | ±(2.5% of reading +10words) | 
| 10A | 0.01A | 
- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
 10A range without insurance
 - Maximum input current: mA: 600mA DC or AC rms;
 10A: 10A DC or AC rms;
 When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
 - Frequency response: 40Hz ~ 1000Hz True RMS.
  
 3.2.5 DC
  
| Range | Resolution | Accuracy | 
| 600.0uA | 0.1uA | ±(1.0% of reading +5words) | 
| 6000uA | 1uA | |
| 60.00mA | 0.01mA | |
| 600.0mA | 0.1mA | |
| 6A | 0.001A | ±(2.0% of reading +10words) | 
| 10A | 0.01A | 
- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
 10A range without insurance
 - Maximum input current: mA: 600mA DC or AC rms;
 10A: 10A DC or AC rms;
 When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
  
  
 3.2.6 Frequency
  
| Range | Resolution | Accuracy | 
| 9.999Hz | 0.001Hz | ±(1.0% of reading +3words) | 
| 99.99Hz | 0.01Hz | |
| 999.9Hz | 0.1Hz | |
| 9.999kHz | 0.001kHz | |
| 99.99KHZ | 0.01kHZ | |
| 999.9KHZ | 0.1KHZ | |
| 9.999MHZ | 0.001MHZ | 
- Overload protection: 250V DC or AC (rms)
 - Input voltage range: 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)
  
  
 3.2.7 Duty cycle
  
| Range | Resolution | Accuracy | 
| 0.1 – 99.9% | 0.1% | ± 3.0% | 
- Frequency response: 10 ~ 10MHz
- Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)
- Maximum input voltage: 250V AC (rms)
  
  
Resistance
  
| Range | Resolution | Accuracy | 
| 600W | 0.1W | ±(0.8% of reading +3words) | 
| 6kW | 0.001kW | |
| 60kW | 0.01kW | |
| 600kW | 0.1kW | |
| 6MW | 0.001MW | ±(1.2% of reading +3words) | 
| 60MW | 0.01MW | 
- Open circuit voltage: approx. 1.0V
 - Overload protection: 250V DC or AC (rms)
  
  
Transistor test
| Range | Description | Test Conditions | 
| hFE | The display reads the approximate value of hFE(0~1000) | Base current of about 10uA; Vce about 2.8V | 
Capacitance
| Range | Resolution | Accuracy | 
| 9.999nF | 0.001nF | ±(4.0% of reading +3words) | 
| 99.99nF | 0.01nF | |
| 999.9nF | 0.1nF | |
| 9.999mF | 0.001mF | |
| 99.99mF | 0.01mF | |
| 999.9mF | 0.1mF | |
| 9.999mF | 0.001mF | ±(5.0% of reading +3words) | 
| 99.99mF | 0.01mF | Not calibrated | 
- Overload protection: 250V DC or AC (rms)
Temperature test
| Range | Accuracy | Resolution | 
| -20℃-300℃ | ±(1.0%+4d) | 1℃ | 
| 301℃-1000℃ | ±(1.9%+5d) | 1℃ | 
| -4℉-600℉ | ±(1.2%+6d) | 1℉ | 
| 601℉-1832℉ | ±(1.9%+6d) | 1℉ | 
- Overload protection: 250V DC or AC (rms)
|   | 
| UK type plug socket tester pro with RCD GFCI Voltage Measurement and LED indication Images | 
 10MΩ 600V Digital Display Multimeter Overload Protection
                                                                                    
                        
                        
                        
                                                            10MΩ 600V Digital Display Multimeter Overload Protection
                                                    
                        
                     Ultra Thin Pocket Size Digital Multimeter Tester Relative Humidity <75%
                                                                                    
                        
                        
                        
                                                            Ultra Thin Pocket Size Digital Multimeter Tester Relative Humidity <75%
                                                    
                        
                     10MΩ 0.01V Portable Digital Multimeter Professional Measuring Instruments
                                                                                    
                        
                        
                        
                                                            10MΩ 0.01V Portable Digital Multimeter Professional Measuring Instruments
                                                    
                        
                     Professional DC AC Digital Smart Multimeter 600V 10MΩ Multi Volt Meter
                                                                                    
                        
                        
                        
                                                            Professional DC AC Digital Smart Multimeter 600V 10MΩ Multi Volt Meter
                                                    
                        
                     Non Contact Voltage Test Digital Multimeter , Anti Shock Universal Digital
                                                                                    
                        
                        
                        
                                                            Non Contact Voltage Test Digital Multimeter , Anti Shock Universal Digital
                                                    
                        
                     Handheld Digital Multimeter Tester AC DC Voltage Measurement 600.0uA
                                                                                    
                        
                        
                        
                                                            Handheld Digital Multimeter Tester AC DC Voltage Measurement 600.0uA
                                                    
                        
                     Automatic Shutdown Digital Smart Multimeter 0.001nF 6V Multi Range AC Voltmeter
                                                                                    
                        
                        
                        
                                                            Automatic Shutdown Digital Smart Multimeter 0.001nF 6V Multi Range AC Voltmeter
                                                    
                        
                     2000 Counts Digital Smart Multimeter 9.999nF 99.99nF 999.9nF
                                                                                    
                        
                        
                        
                                                            2000 Counts Digital Smart Multimeter 9.999nF 99.99nF 999.9nF
                                                    
                        
                     110V 220V Socket Tester Outlet Tester for Home renovation socket check
                                                                                    
                        
                        
                        
                                                            110V 220V Socket Tester Outlet Tester for Home renovation socket check
                                                    
                        
                     EN EURO USA CHINA model GFCI circuit RCD Voltage Smart Socket plug tester
                                                                                    
                        
                        
                        
                                                            EN EURO USA CHINA model GFCI circuit RCD Voltage Smart Socket plug tester